THE BASIC PRINCIPLES OF DP50RB

The Basic Principles Of Dp50rb

The Basic Principles Of Dp50rb

Blog Article

one.two.2 Warning Labels Warning Labels Indicating You should diligently read this handbook in advance of use system. The following labels absolutely are a. Tend not to location the product on the sloped floor. In any other case the available if the method product might slide, causing individual personal injury or maybe the product operates with the cellular malfunction.

Most 4 times tasking for a person transmitted beam, resulting in excellent time resolution and higher body rate.

Get a whole and extended see on the anatomical framework by way of panoramic imaging coupled with velocity sign and forward/backward scan capacity producing scanning much simpler, smoother and a lot more controllable.

Usually do not use any cables aside from the cables furnished While using the gadget by Mindray. three. Utilize the cable provided with this system to attach the printer. Other cables may possibly end in electrical shock. Web page fifteen: Mechanical Basic safety

By continuing your visit on our Web page, you happen to be consenting to our use of cookies. Nonetheless, you'll be able to transform your cookie options at any time.  Cookie choice Take and Continue

Mindray’s new generation of black & white ultrasound method, DP-50 Expert, is supplied with State-of-the-art imaging systems enabling further penetration and speedier picture acquisition with bigger resolution.

S. ought to present the Department using an electronic mail deal with if they may have just one. The email messages delivered could be utilized for official communication With all the licensee. On the other hand e mail addresses are community file. If you do not wish to produce a personal address, make sure you offer the Office having an e mail deal with that may be built available to the public. Make sure you see our Chapter 455 web page to find out For anyone who is impacted by this change.

Find out improved diagnostic facts through prolonged perspective of the anatomical structure on all convex probes.

Assessing individuals in right now’s demanding atmosphere requires impressive technological know-how that permits clinicians to make speedy and confident diagnoses. The flexibility on the DP-fifty expands your clinical utility even though assisting to boost affected individual care.

five.2.three Geometric positioning accuracy Longitudinal geometric positioning precision  Take a look at Phase: Do adjustments as just how in tests the utmost depth. Document the space by 20mm each section within the longitudinal targets line utilizing the measurement caliper; Decide on the value with the greatest mistake (to 20mm), work out the accuracy using the system under The measurement caliper needs to be positioned at the upper fringe of the target, Notice:... Web page 79 Transverse geometric positioning precision  Test Action: Include the scan floor in the phantom with h2o or pair gel, gently Get hold of the probe Using the scan surface area Change the depth, making the transverse targets to get shown from the graphic. Adjust the focus stage for being posited beside Dp50rb the transverse targets (the typical is not really distinct) Adjust parameters like acquire, TGC, producing Every single transverse targets to get Obviously displayed. Website page 80 five.5.two.4 Blackout Area Test Move: Address the scan floor on the phantom with water or pair gel, gently contact the probe With all the scan surface Regulate the depth at a lessen worth, and established the focus at the closest place to the scan floor. Decrease the value of parameters like AP, Gain until eventually the history sounds just could be found. Website page eighty one: Software program Up grade And Routine maintenance

Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

Observe: Prior to uploading the log, make certain the ultrasound process is linked to community, otherwise, the technique may alert “couldn't connect with server” The server (smtp.

Efficiency Exam 5.5.1 Check System Resolution Detection depth Geometric Place Accuracy Blackout space check File the Examination images 5.five.two Test Material The picture applied Here's only for reference, persist with the impression effect in the actual Notice: situation. Prerequisites: Show: established the distinction and brightness at the scientific software worth (or maybe the default status) Operation natural environment: dim place, simulating the medical application setting. Website page seventy six In issue that the transverse resolution testing targets are horizontally displayed, document the minimal distance of two targets which might be clearly acknowledged. Repeat the Procedure above to the transverse resolution testing targets at other depths. As revealed in determine under. Axial resolution ... Page 77 When using the convex probe, continue to keep the transverse resolution testing targets to NOTE: be shown near the midline. When utilizing a linear probe with steer operate, do not turn on the steer function when complete the transverse resolution take a look at. Zoom within the area where by the targets Found if necessary. The diameter from the target stage at a particular depth is equal towards the transverse resolution in the depth. Page 78 five.

Mindray respects your privacy. We use cookies for several different purposes, for example Web site features, bettering your experience of our Web page, building integration with social websites and serving to concentrate on our advertising and marketing.

Notice: Be certain that you could potentially pull out and thrust into the IO board sockets vertically when pulling out and assembling the IO board assembly to the placement of your handle. Take out panhead screws with washers M3X6 (4) accustomed to protected the IO board, and after that you could possibly take out the IO board. Webpage 116 Eliminate panhead screws with washers (2 M3X6) that are set on the principle unit, get out the upper baffle then pull out two cables connecting the main board to the facility module assembly.